Nonintrusive flow measurement with fluxus liquids gases thermal energy nonintrusive process analytics with piox s concentration density mass flow rate piox r process refractometer concentration density brix etc. You can visit the new online user manual by clicking here new best practices for using this answers site. Oct 05, 2016 flexim ultrasonic clampon hazardous area flow meters brochure 1. F5 or ctrle is the key that runs the script when you are ready. Please find below links to the appropriate instructions for each application. Flexim fluxus f601 portable ultrasonic clampon liquid flow meters portable clampon flow meter for liquid measurement for safe area applications flexim s f601 flow meter is a portable clampon solution for safe, nonhazardous area applications which is ideal for. As flexims basic and economic alternative, the adm 5107 offers the same benefits in terms of accuracy and reliability as its bigger brothers, the fluxus adm 7407 and adm. With one or two flow channels and versatile electrical inputs and outputs, the fluxus f704 can optimally be configured to your application needs, measuring and handling a variety of process parameters. Setting standards in clampon ultrasonic liquid flow. Make sure you have read and understood this user manual before using the measuring instrument. Ultrasonic flowmeter for liquids in explosive atmosphere fluxus adm 8027. The operation of the flowmeter is especially easy thanks to the user friendly and clearly structured user dialogue. User manual umfluxus g7v402en ultrasonic flowmeter.
User friendly design applications chemical industry petrochemical industry. Permanent flowmeters for liquids flexim s liquid flow meter series fluxus f sets the standards for noninvasive metering of liquid media. User friendly menu navigation the firmware is specifically adapted to the needs of the water industry. Fluxus adm nonintrusive liquid flow measurement chemical. Clamped on to the pipe wall outside, the bidirectional flow measurement system measures any kind of liquid even at extreme pipe temperatures from. Became wa and nt exclusive distributors for flexim in 2010. Fluxus f601 user manual fum chapter 3 page 15 for more information on theory of operation. Flexim ultrasonic clampon hazardous area flow meters brochure 1. User manual umadm5x07pv12en standard design ultrasonic. Flexim fluxus f721 flow meter noninvasive ultrasonic flow meter for permanent installation benefits.
If particulates or entrained bubbles prevent good transit time measurements, the meter can be configured to use flexim s doppler technology called. User manual umfluxus f7v402en ultrasonic flowmeter. Flexim meters ultrasonic clampon flow meters gas storage industry. The new fluxus f608 zone 2 portable flow meter is has all the features and benefits of the f601, and has been iecex certified for use in hazardous areas. Fluxus adm 5207 flow transducers in transducer shoe, mounted with tension strap. Here you can check liquid flow meters, gas flow meters and ultrasonic clampon transducers from flexim. Technical specification fluxus f601 example for the equipment of a transport case serial data kit power supply, power cable transducer pipe mounting fixture measuring tape transducers transmitter user manual, quick start guide coupling compound wall thickness probe optional quickfix pipe mounting fixture temperature probes optional. Flexim also offers liquid flow meters for usage in atex zone 1 environments, such as the fluxus adm 8027 and fluxus adm 8127 for offshore usage. User manual umfluxus f7v402en ultrasonic flowmeter for. No process interruption for installation, no pipe modification necessary maintenancefree no need for frequent work in hazardous areas certified for operation within hazardous areas fmc class i, div.
Here as well as in all instruments of the fluxus adm series, the digital signal processor dsp and the high number of measuring cycles guarantee stable and reliable measuring results even under difficult conditions. Flexim provides easy solution even for challenging. The housing may only be opened by authorized personnel. Ii approved version, allowing its usage in the respective hazardous areas. The fluxus f721 is a technological breakthrough in the ultrasonic clampon volume and mass flow measurement of liquids. User manual basic functions ultrasonic flowmeter for liquids. An extended status display helps the user to judge the measuring situation and the. Flexim gmbh is a leading manufacturer of clampon ultrasonic flow measurement offering you the ideal flow meters even for the most testing of conditions. Flexim manual supplement thermal energy meter equipment.
Datasheets our datasheets technical specifications are designed to provide you with more information regarding the technical aspects of our devices, their dimensions, the various versions and much more. Flexim fluxus adm 5107 permanent ultrasonic clampon liquid flow meters. Flexim s thermal energy meter fluxus btu is up to the task. Universal sensor adapter 2 ultrasonic couplant gel tubes fluxus software assorted cables view photo of universal sensor. This manual covers features of interest to license administrators and end users in flexlm versions 1.
Flexim fluxus f601 portable ultrasonic clampon liquid. Livingston the test and measurement rental company. External measurement of internal flow flexim ultrasonic. Liquid ultrasonic flowmeter for permanent installation. Flexim fluxus ultrasonic liquid flow meters adm series brochure. Fluxus measures flow noninvasively using ultrasonic technology. Portable flow meter flexim fluxus f608 zone 2 no more hot work permits.
This user manual has been written for the personnel operating the ultrasonic flowmeter fluxus. Flexim fluxus f601 flowmeters is a portable multifunctional clampon flowmeter offering accuracy and reliability even in the most tricky application conditions flexim manufacture marketleading ultrasonic flow meters the flexim fluxus f601 forms part of the portable liquid flowmeter range. Rent, lease or buy the fluxus f601 flexim fluxus f601 from livingston. No process interruption for installation, no pipe modification necessary maintenancefree no need for frequent work in hazardous areas certified for operation within hazardous areas fmc class i. Flexim meters ultrasonic meters hazardous area meters atex.
The fluxus adm 5107 is flexims solution for many flow metering. Misuse of the fluxus will immediately revoke any warranty given or implied. With one or two flow channels and versatile electrical inputs and outputs, the fluxus adm 7407 can optimally be configured to your application needs, measuring and handling a variety of process parameters. Misuse of the fluxus will immediately revoke any warranty given or. User manual umfluxus f7v402en ultrasonic flowmeter for liquids. Fluxus adm 6725 automatic transducer detection portable flow measurement with 2 flow channels automatic transducer detection easy installation without cutting into the pipe and without process interruption usefriendly operation thanks to the clearly structured user dialogue two transducer pairs cover the main diameter range.
Flexim ultrasonic clampon hazardous area flow meters. The degree of protection of the transmitter fluxus adm 7407 a2 and fluxus adm 7407 will only be ensured if. In addition to the adm 5107 which provides 1 measuring channel, the adm 5207 is available which provides 2 measuring channels along with all of the features of the adm 5107. It has an air tight ip65 case that makes the device water, oil and dust resistance, alongside an ip67 waterproof carry case. This work is licensed under creative commons attributionshare alike 2. If you are a system administrator or user, chances are one or more of the products currently on your network is licensed by flexlm. This user manual has been written for the users operating the ultrasonic flowmeter fluxus. Flexims clamp on flow meter, the fluxus f721, is the most versatile meter in the marketplace today. Flexim fluxus adm 7407 liquid ultrasonic flowmeter for. Technical specification fluxus f601 example for the equipment of a transport case serial data kit power supply, power cable transducer pipe mounting fixture measuring tape transducers flowmeter user manual and quick start guide coupling compound wall thickness probe option quickfix pipe mounting fixture for temperature probes option flowmeter. As a technical leader in the field of clampon ultrasonic flow measurement, flexim offers you the ideal flow meter.
Fluxus adm topic btumeter mode name thermal energy measuring and temperature linking, enabler. Aug 14, 2014 video shows the f601 by flexim gmbh in operation. As flexims basic and economic alternative, the adm 5107 offers the same benefits in terms of accuracy and reliability as its bigger brothers, the fluxus adm 7407 and adm 8027. User manual umadm5x07pv12en standard design firmware v5. The fluxus f705 and g705 are atex iecex zone 2 as well as fm class i, division 2 approved and have all the benefits of our standard fluxus flow meters but in a corrosion resistant stainless steel 316l 1. The flexim fluxus f601 portable flowmeter is a portable flow tester that is ideal for chemical, water, waste water, oilgas and aviation industries. Permanent flowmeters for liquids flexims liquid flow meter series fluxus f sets the standards for noninvasive metering of liquid media. If particulates or entrained bubbles prevent good transit time measurements, the meter can be configured to use flexims doppler technology called.
Home flexim fluxus adm 7407 liquid ultrasonic flowmeter for permanent installation. The rugged fluxus adm 7407 and g704 clampon ultrasonic flow meters just got stronger. Clamped on to the pipe wall outside, the bidirectional flow measurement system measures any kind of liquid even at extreme pipe temperatures from 310 f up to 1110 f. Flexim roofing mortar can be used on multiple locations on and around your roof. Request the rental price for the fluxus f601 flexim fluxus f601 by adding it to your shopping cart. Flexim fluxus f601 in stock, we buy sell repair, price quote. As a technical leader in the field of clampon ultrasonic flow measurement, flexim offers you the ideal flow meter even for the most demanding challenges. User friendly design transducers available for a wide range of inner pipe diameters and fluid temperatures, applications down to 276 f possible. A system comprises a transmitter and one or two pairs of special ultrasonic transducers which are simply clamped onto the outside of the pipe and never come in. With atex approval, users no longer need to obtain a hot work permit allowing. You can visit the new online user manual by clicking here. Flexim fluxus adm 5107 ultrasonic liquid flow meters, permanent clampon flow meter, liquid measurement. Fast and easy installation in an application at low.
Any liquidhuge database of liquids preloaded into the clamp on flow meter, challenge us with a new and exotic liquid. Flexim meters ultrasonic meters hazardous area meters. Flexim fluxus adm 7407 liquid ultrasonic flowmeter for permanent installation tweet. It contains important information about the measuring instrument, how to handle it correctly, and how to avoid damages. Ultrasonic flowmeters for liquids permanent flexim fluxus flowmeters. The fluxus adm flow meter measures the flow of liquids using flexims proven clampon transittime correlation technique. Specification of the ultrasonic flowmeter fluxus adm 6725. Wall thickness measurement flow measurement using clampon sensors energy measurements using clampon temperature probes. An extended status display helps the user to judge the measuring situation and. This flexim fluxus f601 ultrasonic flow meter is used and in excellent condition.
Flexim fluxus adm 5107 permanent ultrasonic clampon. The fluxus f608 zone 2 portable flow meter is available for hire or purchase from aquip systems please contact our sales team for more information. User manual umfluxus f8v40en ultrasonic flowmeter for. Flexim fluxus adm 5107 permanent ultrasonic clampon liquid. Flexim fluxus f601 flowmeter ultrasonic clampon liquid. Flexims products are suitable for liquids and gases, extreme temperatures, high pressures and highly variable flow rates in thick walled pipes allowing for solutions to a wide range of applications including hazardous areas. This unit does not include the transducer modules and has been priced accordingly. The fluxus adm 5107 is flexim s solution for many flow metering applications found in the water and wastewater sector and adjacent industries. Fluxus adm 7407 the ultrasonic flow meter for permanent installation. A system comprises a transmitter and one or two pairs of special ultrasonic transducers which are simply clamped onto the outside of the pipe and never come in direct contact with the liquid. With its stateoftheart hardware design and powerful digital signal processing it surpasses any other nonintrusive ultrasonic flowmeter in terms of accuracy, reliability and versatility. Fluxus provides the above user selectable modes that are better suited for chilling or heating operation. For repair and service work, please contact flexim. Fluxus adm 7x07 technical specification flow transmitter technical data fluxus adm 7407 adm 7407.
827 712 120 1079 1478 402 56 272 1053 342 534 334 695 867 538 1321 704 1527 120 735 481 586 609 843 780 297 1084 1335 1487 365 326 1111 817